UNION-GARD 160 CORROSION PREVENTION SYSTEM FOR BURIED HYDRAULIC ELEVATORS CALCULATION GUIDE Information needed to complete this calculation:A. Depth of hole (feet)B. Diameter of hole or casing (inches)C. Diameter of jack cylinder (inches)Formula:Step 1 A x 0.0408579 = DStep 2 B2 - C2 = EStep 3 E x D...
INSTALLATION SPECIFICATIONS INSTALLATION METHODS CALCULATION GUIDE PACKAGING & PRICING UNION-GARDa Division of Dome Services L.L.C.Toll-Free (888)299-GARD Fax (928)425-0163 ...
UNION-GARD 160 CORROSION PREVENTION SYSTEM FOR BURIED HYDRAULIC ELEVATORS PACKAGING & PRICING Effective 01/01/12 5 Gallon Pail ..................... $19.00/gal 55 Gallon Drum ......................$18.00/gal 20 Drums or more ................... $17.50/gal F.O.B. Globe, Arizona 85501 HOME INSTAL...
INSTALLATION SPECIFICATIONS INSTALLATION METHODS CALCULATION GUIDE PACKAGING & PRICING UNION-GARDa Division of Dome Services L.L.C.Toll-Free (888)299-GARD Fax (928)425-0163 ...
UNION-GARD 160 CORROSION PREVENTION SYSTEM FOR BURIED HYDRAULIC ELEVATORSINSTALLATION SPECIFICATIONS PROPERTIESResistivity: 1 to 2 megaohms at ambient temperature.Electric Stability: The voltage required to initiate flow of current is greater than 200 volts.Rheology: Product viscosity low enough to ...