Home > Supplier Discovery > Company Profile
Website Snapshot of INDUS INSTRUMENTS

INDUS INSTRUMENTS

(281) 286-1130

721 Tristar Dr Ste C, Webster, Texas   775981302 , USA

Visit Website Map & Directions

General Info:

ecg & pulse doppler systems for cardiovascular research on mice; electronics contract r&d for medical, scientific, & industrial instrumentation

Products & Services:

  • Indus
  • Instruments
  • Home
  • Ecg
  • Ultrasound
  • Heart
  • Rate
  • Temperature
  • Mice
  • Doppler
  • Non-invasive
  • Non-invasively
  • Blood
  • Velocity
  • Pulse
  • Wave
  • Crystal Biotech

Web Site Results

Mouse Doppler
as heart rate, breath rate, core temperature and SpO2. The unique integrated operating platform supports magnetic accessories and incorporates ultra-low noise, high-resolution ECG... ECG Rate as well as maintain body temperature of the subject. The THM100 is ideal for studies involving mice and can also be used for rats and other small animals (requires an optional pad that is larger). More >> 2011 Indus Instruments, USA ...
 Pulse Oximeter Connector
Oximeter Module OVERVIEW SPECIFICATIONS FAQ DOCUMENTS Specifications Pulse Rate Range 200-999BPM Pulse Rate Resolution 1BPM SpO2 Range 80/100% SpO2 Resolution 1% Pulse Oximeter Sensors... perturbation in either temperature or heart rate can lead to inconsistent results. These units add a new set of data to our experiments, and can serve as a quality control to ensure... survival rate has gone up, and the quality of our surgeries has also improved. Max Z. 2011 Indus Instruments, USA ...
Available Outputs
Module OVERVIEW SPECIFICATIONS FAQ DOCUMENTS Specifications BNC Outputs 8 Channels Sample Rate 4kHz DAC Resolution 16-bit Output Impedance 1 k typical Output Voltage (Selectable...) +/-10.0V +/-5.0V +/-2.0V > +-1.0V > +-0.5V +/-0.2V Maximum Output Current 15mA Slew Rate 12V/ s Settling Time 20 s typical Linearity Error +/-4 LSB Size 6 x 3.5 x 1 inches Weight... of myocardial ischemia/reperfusion requires the utmost attention to detail. Any slight perturbation in either temperature or heart rate can lead to inconsistent results. These units add...
Rats, Bats
Temperature Probe Probe Type Mouse-specific " stainless steel Sensor Type Copper-Constantan thermocouple Accuracy +/-0.1 C after calibration Measurements Numeric Heart Rate 200-999BPM... Respiration Rate 60-300BPM Core Temperature 25-50C Pad Temperature 35-45C SpO2 (with module) 80-100% Waveform ECG Lead I ECG Lead II ECG Lead III Respiration Heart Rate "R-Trigger... or heart rate can lead to inconsistent results. These units add a new set of data to our experiments, and can serve as a quality control to ensure surgeries were performed...
MouseMonitor Tablet
as heart rate, breath rate, core temperature and SpO2. The unique integrated operating platform supports magnetic accessories and incorporates ultra-low noise, high-resolution ECG... functions and conditions, such as body temperature, cardiac and respiratory rates and pattern, and blood pressure, and should be appropriately documented... Maintenance of normal... Screening & Toxicology Studies ECG-based Heart Rate R Trigger High-resolution ECG & Pulse Oximetry Acquisition Expansion modules are available for the MouseMonitor . Click...