Home > Supplier Discovery > Company Profile
Website Snapshot of Duromar Inc

DUROMAR INC

(781) 826-2525

35 Pond Park Rd, Hingham, Massachusetts   02043 , USA

Visit Website Map & Directions

General Info:

Duromar makes high performance epoxy linings, specialty coatings, paints, and rebuilding and resurfacing product for erosion and corrosion problems in a variety of industrial applications. All of our products are Zero VOC and 100% solids.

Products & Services:

  • Coating Lines
  • Coating Systems
  • Coatings - Epoxy

Web Site Results

from the mine separation plant to the Chemical Plant for processing into Phosphoric Acid. The existing railcars were lined with a 40 mil Urethane coating which was failing after..., a selection of the cars previously lined were inspected for coating thickness, appearance, and evidence of sticking product. CURRENT STATUS To date, NO CARS HAVE FAILED INSPECTION... (21oC) before returning the railcars to service. RESULTS This project was started in December 1994. A total of 120 cars have been lined, averaging about two per month. Each year...
DUROMAR Inc. Linings and Specialty Coatings Zero VOC, 100% Solids Call us today781-826-2525 High Performance Linings HPL-2131 HPL-2221 HPL-2510 HPL-4310 HPL-4320 All High... & Process Plants Wastewater Treatment Systems Floors & Concrete Surfaces Wind Energy Zero VOC, 100% SolidsFlooring Products and concrete coating systems Learn More Zero VOC, 100... our complete product line. Download Company InfoAbout Us Technical Information Case Studies Contact Us Distributors/Representatives Popular ProductsHPL-2131 HPL-2221 HPL-2510 HPL...
the existing Hastaloy lined outlet duct ended. SOLUTION DUROMAR, INC. was contacted, and we recommended coating a 12 strip of HPL 4330 around the Hastaloy edge, about 3 onto... to coat the existing Hastaloy line outlet duct edge to prevent further corrosion. RESULTS After six months of operation, the HPL 4330 lining was still in perfect condition. More...
into Phosphoric Acid. The existing railcars were lined with a 40 mil Urethane coating which was failing after a few years of service. The failure was from a combination... Hastaloy lined outlet duct ended. FGD Reaction Tank Lining PROBLEM A South-Central Utility installed limestone SO2 scrubber systems on their 720 MW units in 1985 and 1987. The... Reaction Tank walls and ceilings were originally lined with a thick FRP mat product. This lining started to fail within the first year of operation. The failure mode was delamination...
Ads by Openfos

Also Viewed