Home > Supplier Discovery > Company Profile
Website Snapshot of WSA Engineered Systems, Inc.

WSA ENGINEERED SYSTEMS, INC.

(414) 481-4120

2018 S. 1st Street, Milwaukee, Wisconsin   53207 , USA

Visit Website Map & Directions

General Info:

WSA manufactures on-line Brush-type Automatic Tube Cleaning Systems, Ball-type Automatic Tube Cleaning Systems and Automatic Backwash Systems for heat exchangers (shell and tube, as well as plate and frame), chillers, condensers. Website: www.wsaes.com

Products & Services:

  • Valves
  • Flow Diverter
  • Tube Cleaning
  • Brush System
  • Ball System
  • Backwash System
  • Chiller
  • Heat Exchanger
  • Condenser
  • Brush Cleaning
  • Condenser Tube Cleaning

Web Site Results

in the fouling factor by use of a WSA system has consistently produced a reduction in energy consumption of 10 to 25%. With WSAs simple method of continuously cleaning condenser... of the most frequently monitored parameters is surface condenser cleanliness. This parameter can be directly related to condenser backpressure and net station heat rate. Condenser... tube micro and macro fouling, as well as scaling, contribute up to 50% of the total condenser tube heat transfer resistance, resulting in reduction in power generation, increase...
installed on the chiller condenser and steam condenser. The WSA system prevents build up of deposits which waste energy by interfering with proper heat transfer. The fouling factor is now... around the Freon condenser would indicate a gradual loss in heat transfer performance due to fouling of the cooling water tubes by hard scale. This in turn was reflected..., there has been no unscheduled shutdowns to clean the condenser and the compressor loading has continuously been typical of a clean, start-up condition. After one year of service...
/Refinery and Industrial Process markets globally. HVAC/Commercial within both the shell-tube type and plate-frame type heat exchangers/ chiller-condensers. Federal / State... Power Generation Power Plant Surface Condensers Auxiliary Heat Exchangers / Coolers Hydrogen Coolers Petrochemical/Refinery Surface Condensers Produced Water Trim Coolers Raw...
ball
condensers, large chiller systems, auxiliary heat exchangers, and often are found in the following: Power Plants (Fossil, Nuclear, Geothermal, Cogeneration) District Heating... and Cooling Plants Desalinization Plants Petrochemical and Refining Plants This type of ATCS is applied exclusively to condensers and heat exchangers with water tubeside. The Ball type ATCS... to the injection site(s). The balls are injected into the cold leg of the circulating cooling water system serving the condenser or heat exchanger so as to achieve a random distribution within...
Contact Us Problems...Solutions...Results Problem: If you are responsible for a heat exchanger, chiller, or condenser, then you know heat exchanger tubeside / plateside fouling reduces...

Company Profile:

Contact: 414-481-4120
Address: 2018 S. 1st Street
Milwaukee, Wisconsin   53207 , USA
Url: http://www.wsaes.com
Fax: 414-481-4121
   
Year Established: 1971
Annual Sales: US$2.5 Million - US$5 Million
Business Type: Manufacturer
Ads by Openfos