tonnage monitors, i/o modules, load cells, in-die piezoelectric transducers for metal stamping presses using high output, high noise immunity piezoelectric transducers.

Products & Services:

  • Load Monitors
  • Tonnage Monitors
  • Mechanical Presses
  • Metal Stamping Presses
  • Forging
  • Transducers
  • Piezoelectric Transducers
  • Metalforming Presses
  • Load Cells
  • Force Sensor
  • I/o Modules
  • In-die Transducers
  • Stamping Dies
  • Tool And Die
  • Tool Design
  • Metal Stamping Dies
  • Load Monitoring
  • Plc
  • Parts Counter
  • Press Overload
  • Tonnage Measurement
  • Malfunction Detectors
  • Parts Ejection
  • Infra Red Light Barriers
  • Tonnage Monitoring
  • Light Barries
  • Infra Red Windows
  • Parts Specifications
  • Quality Control Systems
  • Job Shops
  • Progressive Dies
  • Programmable Limit Controller
  • Adaptive Learning
  • Waveform
  • Press Brakes
  • In-die Detection Systems
  • Die Sets
  • Die Punches
  • Calibration Equipment
  • Scope Output
  • Piezoelectric Sensors

Web Site Results

High Limit Trigger Trim Module TLD 440
, the overload light for that channel should come on. If it does not, turn the 5K pot counter clockwise until the overload indicator light triggers on. Then turn the Control Knob to its... full clockwise position, depress the calibrate button and while holding the calibrate button depressed, turn the Control Knob counter clockwise to the 100% mark. The overload light... reference to the above drawing, the 5K pot sets the zero Trip Point without pressing the calibrate switch. The 10K pot sets the 100% Trip Point with the calibrate button depressed...
IMCO Digital Two Channel Hi Low Tonnage Load Monitor with Oveload Counter and Parts Counter
disengagement, and greatly reduce the possibility of a damaging overload to both dies and press. Monitor Control Knobs read out in Direct Tons or Percent Rated Capacity depending on the type... the advantage of monitoring for under loads as well as overloads. Ideally suited for automatic press line operations and where similar production requirements generate the importance... of maintaining suitable under and overloads on dies. The user first observes the load being applied to press dies, while at the same time relates the load to the analog or digital displays...
Low Limit Trigger Trim Module TLD 440
with the calibrate button depressed until the red led indicator light triggers on. In reference to the above drawing, the 5K pot sets the zero Trip Point without pressing the calibrate... must do this until the gap between the two pots disappears. It will also be necessary to reset the system each time you cause the system to overload. The method for setting... the Trip Points on High Limit are the same, except on the High Limit the overload indicator light on the face plate is used as the indicator. ...
MECHANICAL STAMPING PRESSES
still maintaining overload limits for the mechanical metal stamping press. Manually set or Adaptive Learning, IMCO Piezoelectric Tonnage Load Monitors provide many standard...Tonnage Load Monitors, Piezoelectric Transducers, I/O Modules,... You can have less wear on your Mechanical Stamping Presses and Tooling. Less maintenance, downtime and expensive... repairs on your Presses and Dies while operating at maximum load output efficiency within your rated Press capacity using our Tonnage Monitors. TONNAGE MONITORS LOAD MONITORS USED...