Home > Supplier Discovery > Company Profile
Website Snapshot of Kaman Measuring Systems Corporation

KAMAN MEASURING SYSTEMS CORPORATION

860-632-4573,800-552-6267

217 Smith St., Middletown, Connecticut   06457 , USA

Visit Website Map & Directions

General Info:

Kaman Precision | Position sensors | non-contact | high-resolution | high-precision | inductive eddy-current systems - Products

Products & Services:

  • Inductive Sensor
  • Eddy Current Sensor
  • Eddy Current
  • Noncontact Position Sensor
  • Non-contact Position Sensor
  • High Resolution Sensor
  • High Performance Sensor
  • Displacement Sensor
  • High Performance Position Sensor
  • Position Measuring System
  • Oem Position Sensor
  • Extreme Sensor
  • Built-to-print Electro-mechanical

Web Site Results

Kaman Precision Position sensors non-contact high-resolution... PRODUCTS Overview/Help KD-2300 KD-2306 KD-2446 KDM-8200 SMU-9000 SMT-9700 DIT-5200 DIT-5200L KD-5100 Extreme... the published range. However, linearity, thermal stability, resolution and repeatability specs will suffer. ENVIRONMENT Q: Does humidity affect the sensor output? A: No, not like... displacement sensor over a capacitance displacement sensor? A: It essentially comes down to environment and performance requirements. Unlike eddy current sensors, capacitance...
Kaman Precision Position sensors non-contact high-resolution... PRODUCTS Overview/Help KD-2306 KD-2446 KDM-8206 SMT-9700 DIT-5200 DIT-5200L KD-5100 Extreme Environment...
Kaman-KD-5100
-ferrous metal targets, the KD-2306 includes electronics, sensor, and interconnecting cable. Standard sensing ranges are from 0.02 to 2.4 , with 0.01%FS resolution or better, with non... COMPANY Vision & History Locations Corporate CONTACTS Kaman's New RoHS Compliant Product KD-2306! KAMAN S NEW MEASURING SYSTEM COMBINES MULTIPLE HIGH-GAIN OUTPUT WITH EASY CALIBRATION... AND SYNCHRONIZATION Kaman s KD-2306, a non-contact linear displacement measuring instrument based on proven balanced bridge eddy current technology, is simple to use, makes high...
range extension image
output with good linearity and usable resolution. If your application cannot support the use of a standard sensor calibrated over a standard range, we can offer extended range... to meet published performance specifications. There are times when physical constraints prevent the use of a larger sensor with the range capability required of the application... current sensors work because there is a change in the sensor coil's inductance with changes in distance between the coil and the target. This diagram shows a typical inductance curve...
Kaman Precision Position sensors non-contact high-resolution... PRODUCTS Overview/Help KD-2306 KD-2446 KDM-8206 SMT-9700 DIT-5200 DIT-5200L KD-5100 Extreme Environment...
Ads by Openfos

Also Viewed